MEDECO 12.1

MEDECO 12.1" color TFT screen Monitor 9000 Multi‐channel display Big font interface ST and arrhythmia analysis Drug dose calculation and titration table OxyCRG dynamic view display Respiration monitoring with apnea alarms Alarm review, arrhythmia review Patient info. Input Anti‐defibrillation design NIBP over pressure protection Plug‐in rechargeable battery, AC/DC available. Supporting wire or wireless network.

Request Quote

DOCUMENTS & RESOURCES

Description

MEDECO 12.1" color TFT screen Monitor 9000

Multichannel display

Big font interface

ST and arrhythmia analysis

Drug dose calculation and titration table

OxyCRG dynamic view display

Respiration monitoring with apnea alarms

Alarm review, arrhythmia review

Patient info. Input

Antidefibrillation design

NIBP over pressure protection

Plugin rechargeable battery, AC/DC available.

Supporting wire or wireless network.

Technical Specifications

ECG

Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection                     I, II, III, avR, avL, avF, V

Wavef orm                          2 ch

Lead mode                          3 Leads ( R, L, F or RA, LA, LL)

Lead selection                     I, II, III,

Wave form                          1 ch

Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

HR and Alarm Range                 Adult    15 ~ 300 bpm

Neo/Ped    15 ~ 350 bpm

Accuracy                           ±1% or±1bpm, which is greater

Resolution                         1 bpm

Sensitivity                        > 200 (uVp-p)

Differential Input Impedance       > 5 MΩ

CMRR                                   Monitor > 105 dB

Operation > 105 dB

Diagnosis > 85 dB

Electrode offset potential         ±300mV

Leakage Current                    < 10 uA

Baseline Recovery                  < 3 S After Defi.

ECG Signal Range                   ±8 m V ( Vp-p )

Bandwidth                           Surgery    1 ~ 20 Hz

Monitor     0.5 ~ 40 Hz

Diagnostic  0.05 ~ 130 Hz

Calibration Signal                  1 (mVp-p),  Accuracy:5%

ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,

PNP, PNC,Alarm Available,Review Available

Respiration

Method                               Impedance between R-F(RA-LL)

Differential Input Impedance       > 2.5 MΩ

Measuring Impedance Range          0.3~3 Ω

Base line Impedance Range           200~4 KΩ

Bandwidth                          0.1~2.5Hz

Resp. Rate                         Measuring and Alarm Range

Adult 0 ~ 120 Brpm

Neo/Ped 0 ~ 150 Brpm

Resolution 1 Brpm

Accuracy ±2 Brpm

Apnea Alarm                        10 ~ 40 S

NIBP

Method                            Oscillometric

Mode                              Manual, Auto, STAT

Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

Measuring Period in STAT Mode     5 Min

Pulse Rate Range              40 ~ 240 bpm

Alarm Type                        SYS, DIA, MEAN

Measuring and alarm range        Adult Mode

SYS 40 ~ 270 mmHg

DIA 10 ~ 215 mmHg

MEAN 20 ~ 235 mmHg

Pediatric Mode

SYS 40 ~ 200 mmHg

DIA 10 ~ 150 mmHg

MEAN 20 ~ 165 mmHg

Neonatal Mode

SYS 40 ~ 135 mmHg

DIA 10 ~ 100 mmHg

MEAN 20 ~ 110 mmHg

Resolution                      1mmHg

Accuracy                        Maximum Mean error ±5mmHg

Maximum Standard deviation ±8mmHg

Overpressure Protection          Adult Mode 297±3 mmHg

Pediatric Mode 240±3 mmHg

Neonatal Mode 147±3 mmHg

SpO2

Measuring Range                  0 ~ 100 %

Alarm Range                      0 ~ 100 %

Resolution                       1 %

Accuracy                         70% ~ 100%  2 %

0%  ~  69% unspecified

Actualization intervalabout      1 Sec.

Alarm Delay                      10 Sec.

Pulse Rate                       Measuring and Alarm Range 20~300 bpm

Resolution       1bpm

Accuracy ±3bpm

TEMP

Channel                          2

Measuring and Alarm Range  0 ~ 50

Resolution                      0.1

Accuracy ±0.2

Actualization intervalabout     1 Sec.

Average Time Constant           < 10 Sec.

IBP

Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range       ART 0 ~ 300 mmHg

PA -6 ~ 120 mmHg

CVP/RAP/LAP/ICP-10 ~ 40 mmHg

P1 / P2-10 ~ 300 mmHg

Press Sensor                    Sensitivity 5  uV/V/mmHg

Impedance 300-3000Ω

Resolution                      1 mmHg

Accuracy                        ±2% or 1mmHg which is greater

Actualization interval               about 1 secretary