MEDECO 9000D 15

MEDECO 9000D 15" monitor 15" color TFT screen Multi-channel display Big font interface ST and arrhythmia analysis Drug dose calculation and titration table OxyCRG dynamic view display Respiration monitoring with apnea alarms Alarm review, arrhythmia review Patient info. Input Anti-defibrillation design NIBP over pressure protection Plug-in rechargeable battery, AC/DC available. Supporting wire or wireless network.

Request Quote

DOCUMENTS & RESOURCES

Description

MEDECO 9000D 15" Patient Monitor

15" color TFT screen Multi-channel display Big font interface

ST and arrhythmia analysis

Drug dose calculation and titration table

OxyCRG dynamic view display

Respiration monitoring with apnea alarms

Alarm review, arrhythmia review

Patient info. Input

Anti-defibrillation design

NIBP over pressure protection

Plug-in rechargeable battery, AC/DC available. Supporting wire or wireless network.

ECG

Lead mode               5 Leads, I, II, III, AVR, AVL, AVF, V

Gain                   ×2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV,auto

Heart rate             Measure range:

Adult    15 ~ 300 bpm

Neonatal/Pediatric 15 ~ 350 bpm

Accuracy                ±1%

Resolution              1 bpm

Sensitivity             > 200 VμP-P

Differential Input Impedance      > 5 M ohm

CMRR                              Monitor Mode   >100 dB

Surgery Mode >100 dB

Diagnostic Mode  >90 dB

Electrode offset potential     ±300mV

Leakage Current                < 10 μA

PACE pulse detect              range±2~±700mV

width 0.1~2ms

rise time 10~100 μs

PACE pulse rejection           range ±2 ~±700mV

width 0.1~2ms

rise time 10 ~100 μs

Baseline Recovery              < 3 s After defibrillation.

Signal Range                   ±8 mV p-p

Bandwidth                        Surgery      1 ~ 20 Hz

Monitor      0.5 ~ 40 Hz

Diagnostic   0.05 ~ 130 Hz

Calibration Signal             1 mV p-p, 5% accuracy

ST measurement                 Range -2.0 ~+2.0 mV

Accuracy-0.8mV~+0.8mV

±0.02mV or±10%, which is greater

Other range: unspecified

Respiration

Method                         Impedance between RA-LL

Differential Input Impedance   >2.5 MΩ

Respiration Impedance Range     0.3~3Ω

Base Impedance Range           200Ω~4000Ω

Bandwidth                     0.1 ~ 2.5 Hz

Gain                          ×0.25,×0.500,×1,×2,×4

Respiration Rate               Measurement Range

Adult 0 ~ 120 BrPM

Neonatal / Pediatric 0 ~ 150 BrPM

Resolution                     1 BrPM

Accuracy                 0~6 BrPM: unspecified

7~150 BrPM:±2 BrPM or±2%

use the greater

Inspiriting current          < 300 A RMS max

Apnea Alarm                   10 ~ 40 s

NIBP

Method                            Oscillometry

Measure mode                      Manual, Auto, Continual

Measure Interval in AUTO Mode     1,2,3,4,5,10,15,30,60,90,120,180,240,480 min

Measure Period in Continual Mode    5 min

Pulse Rate Range               40 ~ 240 bpm

Measure and Alarm Range        Adult Mode

SYS 40 ~ 270 mmHg

DIA 10 ~ 215 mmHg

MEAN20 ~ 235 mmHg

Pediatric Mode

SYS 40 ~ 220 mmHg 

DIA 10 ~ 150 mmHg

MEAN20 ~ 165 mmHg

Neonatal Mode

SYS 40 ~ 135 mmHg

DIA 10 ~ 100 mmHg

MEAN 20 ~ 110 mmHg

Static pressure accuracy       ±3mmHg

Resolution                     1mmHg

Accuracy                       Maximum Mean error  ±5mmHg

Maximum Standard deviation     8mmHg

Overpressure Protection        Adult 297±3 mmHg

Pediatric 240±3 mmHg

Neonatal 147±3 mmHg

SpO2

Measurement Range              0 ~ 100 %

Resolution                     1 %

Accuracy                      70% ~ 100% ±2 %

69%

0% ~ 39%  unspecified

Pulse Rate                    Measure and Alarm Range 20~300bpm

Resolution 1bpm

Accuracy ±3bpm

TEMP

Channel                       2

Measure and Alarm Range       0 ~ 50

Resolution                    0.1

Accuracy(no sensor) ±0.1(25-45),0.2±℃(other)

Accuracy(include sensor) ±0.2(32-42)

±0.3(other)

tandard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature

Optional:  EtCO2, IBP, Thermal Recorder

Request Quote